Part Number Hot Search : 
CY2277A VRE404C HCT57 16244 TDA514 MJE13007 00002 2N60C3
Product Description
Full Text Search
 

To Download PA-120N54CD Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 120W Single Output Power Supply or Battery Charger
Features :
PA / P B - 1 2 0
series
AC input range selected by switch Built-in passive PFC function compliance to EN61000-3-2 With AC ON-OFF switch 3 poles AC inlet with fuse holder Protections: Short circuit / Overload / Over voltage / Over temperature Charger type can be selected (Optional) Charger for lead-acid batteries 2 color LED loading indicator Open frame models available (Without safety approval) Low cost, High reliability 2 years warranty
TUV Rheinland Product Safety
geprUfre Sicherheit
S:Power Supply A:Voltage detector B:Current detector P:With PFC N:None PFC
PA
120 P
13 C :O.D.M. number P:Open P.C.B. C:With case 13:13.8V 27:27.6V 54:55.2V
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT OUTPUT CURRENT RANGE RATED POWER LED INDICATED VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. PA/PB-120 13.8V 7.2A 0 ~ 7.2A 99.36W PA series voltage 105% 1% PB series load 46% 10% 47 ~ 63Hz >0.65 (with PFC series) 73% 3A/115VAC 1.5A/230VAC COLD START 25A/115VAC <1.5mA / 240VAC 90 ~ 110% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 15 ~ 17V 30 ~ 35V 60 ~ 66V Protection type : Hiccup mode, recovers automatically after fault condition is removed RTH2 70 10 detect on RTH2 thermistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +45 (Refer to output load derating curve) 79% 50A/230VAC 79% -13 PA/PB-120 27.6V 4.3A 0 ~ 4.3A 118.68W : RED / 105% 1% :GREEN :RED : GREEN / 46% 10% -27 PA/PB-120 55.2V 2.2A 0 ~ 2.2A 121.44W -54
88 ~ 132VAC / 176 ~ 264VAC selected by switch
20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.05%/ (0 ~ 45 VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 4)
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE HARMONIC CURRENT EMS IMMUNITY
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 149.6K hrs min. MIL-HDBK-217F (25 ) PCB Type:144*90*33mm External case type:180*96*49mm (L*W*H) 1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC) 1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC)
OTHERS
NOTE
MTBF DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. With PFC I/P range: 95~132VAC/190~264VAC. 6. For open P.C.B. WITH 17.8CFM min. Forced air.
File Name:PA,PB-120-SPEC 2008-05-06
120W Single Output Power Supply or Battery Charger
Mechanical Specification
PA / P B - 1 2 0
Case No. PS-120A
series
Unit:mm
1 3
2
CASE: Output cable length=183cm 5cm
Pin No. 1 2,3 Assignment DC OUTPUT +V DC OUTPUT -V
PCB: AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
4180 144 134 5
DC Output Connector (CN3) : JST B4P-VH or equivalent
1234
Pin No. 1,2 3,4
Assignment -V +V
Mating Housing JST VHR or equivalent
Terminal JST SVH-21T-P1.1 or equivalent
5
CN3 +V
90
80
12VDC FAN Output Connector (CN4) : JST B2B-XH or equivalent
Pin No. 1 2 Assignment +V -V Mating Housing JST XHP or equivalent Terminal JST SXH-001T-P0.6 or equivalent
ADJ.
CN4 F4A/250V 12 +CN5 123 CN1 SHORT FOR 115V OPEN FOR 230V
LED
115/230V selected by switch Connector (CN5) : JST B2P-VH or equivalent
Switch 115V 230V Assignment Short Open Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
33
Derating Curve
2 max.
Charging Curve
Vout 105% 100% Bat. Voltage Iout
100
80
Open frame series 17.8CFM air cooling (L=15cm face HS) Other series LED COLOR Vout 105% 100%
Charging Current
100% 45%
60
Red
Green
T
LOAD (%)
Type A:Voltage detecter,pulse charger
40
Bat. Voltage
Iout
20
Charging Current
-10 0 10 20 30 40 50 60 (HORIZONTAL)
100%
AMBIENT TEMPERATURE ( )
LED COLOR
Red Green Type B:Current detecter,2 voltage section
T
File Name:PA,PB-120-SPEC 2008-05-06
-V
49
115
FUSE
3. 8


▲Up To Search▲   

 
Price & Availability of PA-120N54CD

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X